Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 95(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38436450

RESUMO

Magnetized Liner Inertial Fusion experiments have been performed at the Z facility at Sandia National Laboratories. These experiments use deuterium fuel, which produces 2.45 MeV neutrons on reaching thermonuclear conditions. To study the spatial structure of neutron production, the one-dimensional imager of neutrons diagnostic was fielded to record axial resolved neutron images. In this diagnostic, neutrons passing through a rolled edge aperture form an image on a CR-39-based solid state nuclear track detector. Here, we present a modified generalized expectation-maximization algorithm to reconstruct an axial neutron emission profile of the stagnated fusion plasma. We validate the approach by comparing the reconstructed neutron emission profile to an x-ray emission profile provided by a time-integrated pinhole camera.

2.
Rev Sci Instrum ; 94(11)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37916914

RESUMO

Inertial confinement fusion and inertial fusion energy experiments diagnose the geometry of the fusion region through imaging of the neutrons released through fusion reactions. Pinhole arrays typically used for such imaging require thick substrates to obtain high contrast along with a small pinhole diameter to obtain high resolution capability, resulting in pinholes that have large aspect ratios. This leads to expensive pinhole arrays that have small solid angles and are difficult to align. Here, we propose a coded aperture with scatter and partial attenuation (CASPA) for fusion neutron imaging that relaxes the thick substrate requirement for good image contrast. These coded apertures are expected to scale to larger solid angles and are easier to align without sacrificing imaging resolution or throughput. We use Monte Carlo simulations (Geant4) to explore a coded aperture design to measure neutron implosion asymmetries on fusion experiments at the National Ignition Facility (NIF) and discuss the viability of this technique, matching the current nominal resolution of 10 µm. The results show that a 10 mm thick tungsten CASPA can image NIF implosions with neutron yields above 1014 with quality comparable to unprocessed data from a current NIF neutron imaging aperture. This CASPA substrate is 20 times thinner than the current aperture arrays for fusion neutron imaging and less than one mean free-path of 14.1 MeV neutrons through the substrate. Since the resolution, solid angle, and throughput are decoupled in coded aperture imaging, the resolution and solid angle achievable with future designs will be limited primarily by manufacturing capability.

3.
Phys Rev Lett ; 131(6): 065101, 2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37625041

RESUMO

The change in the power balance, temporal dynamics, emission weighted size, temperature, mass, and areal density of inertially confined fusion plasmas have been quantified for experiments that reach target gains up to 0.72. It is observed that as the target gain rises, increased rates of self-heating initially overcome expansion power losses. This leads to reacting plasmas that reach peak fusion production at later times with increased size, temperature, mass and with lower emission weighted areal densities. Analytic models are consistent with the observations and inferences for how these quantities evolve as the rate of fusion self-heating, fusion yield, and target gain increase. At peak fusion production, it is found that as temperatures and target gains rise, the expansion power loss increases to a near constant ratio of the fusion self-heating power. This is consistent with models that indicate that the expansion losses dominate the dynamics in this regime.

4.
Rev Sci Instrum ; 94(2): 021101, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36859056

RESUMO

We review experimental neutron imaging of inertial confinement fusion sources, including the neutron imaging systems that have been used in our measurements at the National Ignition Facility. These systems allow measurements with 10 µm resolution for fusion deuterium-deuterium and deuterium-tritium neutron sources with mean radius up to 400 µm, including measurements of neutrons scattered to lower energy in the remaining cold fuel. These measurements are critical for understanding the fusion burn volume and the three-dimensional effects that can reduce the neutron yields.

5.
Phys Rev Lett ; 127(12): 125001, 2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34597087

RESUMO

Inertial confinement fusion implosions designed to have minimal fluid motion at peak compression often show significant linear flows in the laboratory, attributable per simulations to percent-level imbalances in the laser drive illumination symmetry. We present experimental results which intentionally varied the mode 1 drive imbalance by up to 4% to test hydrodynamic predictions of flows and the resultant imploded core asymmetries and performance, as measured by a combination of DT neutron spectroscopy and high-resolution x-ray core imaging. Neutron yields decrease by up to 50%, and anisotropic neutron Doppler broadening increases by 20%, in agreement with simulations. Furthermore, a tracer jet from the capsule fill-tube perturbation that is entrained by the hot-spot flow confirms the average flow speeds deduced from neutron spectroscopy.

6.
Rev Sci Instrum ; 92(5): 053526, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243327

RESUMO

Recent inertial confinement fusion measurements have highlighted the importance of 3D asymmetry effects on implosion performance. One prominent example is the bulk drift velocity of the deuterium-tritium plasma undergoing fusion ("hotspot"), vHS. Upgrades to the National Ignition Facility neutron time-of-flight diagnostics now provide vHS to better than 1 part in 104 and enable cross correlations with other measurements. This work presents the impact of vHS on the neutron yield, downscatter ratio, apparent ion temperature, electron temperature, and 2D x-ray emission. The necessary improvements to diagnostic suites to take these measurements are also detailed. The benefits of using cross-diagnostic analysis to test hotspot models and theory are discussed, and cross-shot trends are shown.

7.
Rev Sci Instrum ; 92(3): 033508, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820056

RESUMO

Inertial confinement fusion capsule implosions produce neutron, gamma-ray, and x-ray emission, which are recorded by a variety of detectors, both time integrated and time resolved, to determine the performance of the implosion. Two-dimensional emission images from multiple directions can now be combined to infer three-dimensional structures in the implosion, such as the distribution of thermonuclear fuel density, carbon ablator, and impurities. Because of the cost and complexity of the imaging systems, however, only a few measurements can be made, so reconstructions of the source must be made from a limited number of views. Here, a cylindrical-harmonics decomposition technique to reconstruct the three-dimensional object from two views in the same symmetry plane is presented. In the limit of zero order, this method recovers the Abel inversion method. The detailed algorithms used for this characterization and the resulting reconstructed neutron source from an experiment collected at the National Ignition Facility are presented.

8.
Phys Rev Lett ; 124(14): 145001, 2020 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-32338978

RESUMO

The impact to fusion energy production due to the radiative loss from a localized mix in inertial confinement implosions using high density carbon capsule targets has been quantified. The radiative loss from the localized mix and local cooling of the reacting plasma conditions was quantified using neutron and x-ray images to reconstruct the hot spot conditions during thermonuclear burn. Such localized features arise from ablator material that is injected into the hot spot from the Rayleigh-Taylor growth of capsule surface perturbations, particularly the tube used to fill the capsule with deuterium and tritium fuel. Observations, consistent with analytic estimates, show the degradation to fusion energy production to be linearly proportional to the fraction of the total emission that is associated with injected ablator material and that this radiative loss has been the primary source of variations, of up to 1.6 times, in observed fusion energy production. Reducing the fill tube diameter has increased the ignition metric χ_{no α} from 0.49 to 0.72, 92% of that required to achieve a burning hot spot.

9.
Rev Sci Instrum ; 89(10): 10I127, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399819

RESUMO

The current construction of a new nuclear-imaging view at the National Ignition Facility will provide a third line of sight for hotspot and cold fuel imaging and the first dedicated line of sight for 4.4-MeV γ-ray imaging of the remaining carbon ablator. To minimize the effort required to hold and align apertures inside the vacuum chamber, the apertures for the two lines of sight will be contained in the same array. In this work, we discuss the system requirements for neutron and γ-ray imaging and the resulting aperture array design.

10.
Phys Rev Lett ; 120(24): 245003, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29956968

RESUMO

A series of cryogenic, layered deuterium-tritium (DT) implosions have produced, for the first time, fusion energy output twice the peak kinetic energy of the imploding shell. These experiments at the National Ignition Facility utilized high density carbon ablators with a three-shock laser pulse (1.5 MJ in 7.5 ns) to irradiate low gas-filled (0.3 mg/cc of helium) bare depleted uranium hohlraums, resulting in a peak hohlraum radiative temperature ∼290 eV. The imploding shell, composed of the nonablated high density carbon and the DT cryogenic layer, is, thus, driven to velocity on the order of 380 km/s resulting in a peak kinetic energy of ∼21 kJ, which once stagnated produced a total DT neutron yield of 1.9×10^{16} (shot N170827) corresponding to an output fusion energy of 54 kJ. Time dependent low mode asymmetries that limited further progress of implosions have now been controlled, leading to an increased compression of the hot spot. It resulted in hot spot areal density (ρr∼0.3 g/cm^{2}) and stagnation pressure (∼360 Gbar) never before achieved in a laboratory experiment.

11.
Rev Sci Instrum ; 87(11): 11E715, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910388

RESUMO

The Neutron Imaging System at the National Ignition Facility is used to observe the primary ∼14 MeV neutrons from the hotspot and down-scattered neutrons (6-12 MeV) from the assembled shell. Due to the strong spatial dependence of the primary neutron fluence through the dense shell, the down-scattered image is convolved with the primary-neutron fluence much like a backlighter profile. Using a characteristic scattering angle assumption, we estimate the primary neutron fluence and compensate the down-scattered image, which reveals information about asymmetry that is otherwise difficult to extract without invoking complicated models.

12.
Rev Sci Instrum ; 87(11): 11D821, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910447

RESUMO

The installation of a neutron imaging diagnostic with a polar view at the National Ignition Facility (NIF) required design of a new aperture, an extended pinhole array (PHA). This PHA is different from the pinhole array for the existing equatorial system due to significant changes in the alignment and recording systems. The complex set of component requirements, as well as significant space constraints in its intended location, makes the design of this aperture challenging. In addition, lessons learned from development of prior apertures mandate careful aperture metrology prior to first use. This paper discusses the PHA requirements, constraints, and the final design. The PHA design is complex due to size constraints, machining precision, assembly tolerances, and design requirements. When fully assembled, the aperture is a 15 mm × 15 mm × 200 mm tungsten and gold assembly. The PHA body is made from 2 layers of tungsten and 11 layers of gold. The gold layers include 4 layers containing penumbral openings, 4 layers containing pinholes and 3 spacer layers. In total, there are 64 individual, triangular pinholes with a field of view (FOV) of 200 µm and 6 penumbral apertures. Each pinhole is pointed to a slightly different location in the target plane, making the effective FOV of this PHA a 700 µm square in the target plane. The large FOV of the PHA reduces the alignment requirements both for the PHA and the target, allowing for alignment with a laser tracking system at NIF.

13.
Rev Sci Instrum ; 87(11): 11D703, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910487

RESUMO

X-ray and neutrons are commonly used to image inertial confinement fusion implosions, providing key diagnostic information on the fuel assembly of burning deuterium-tritium (DT) fuel. The x-ray and neutron data provided are complementary as the production of neutrons and x-rays occurs from different physical processes, but typically these two images are collected from different views with no opportunity for co-registration of the two images. Neutrons are produced where the DT fusion fuel is burning; X-rays are produced in regions corresponding to high temperatures. Processes such as mix of ablator material into the hotspot can result in increased x-ray production and decreased neutron production but can only be confidently observed if the two images are collected along the same line of sight and co-registered. To allow direct comparison of x-ray and neutron data, a combined neutron x-ray imaging system has been tested at Omega and installed at the National Ignition Facility to collect an x-ray image along the currently installed neutron imaging line of sight. This system is described, and initial results are presented along with prospects for definitive coregistration of the images.

14.
Phys Rev Lett ; 115(10): 105001, 2015 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-26382681

RESUMO

Hydrodynamic instabilities can cause capsule defects and other perturbations to grow and degrade implosion performance in ignition experiments at the National Ignition Facility (NIF). Here, we show the first experimental demonstration that a strong unsupported first shock in indirect drive implosions at the NIF reduces ablation front instability growth leading to a 3 to 10 times higher yield with fuel ρR>1 g/cm(2). This work shows the importance of ablation front instability growth during the National Ignition Campaign and may provide a path to improved performance at the high compression necessary for ignition.

15.
Phys Rev Lett ; 115(5): 055001, 2015 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-26274424

RESUMO

We report on the first layered deuterium-tritium (DT) capsule implosions indirectly driven by a "high-foot" laser pulse that were fielded in depleted uranium hohlraums at the National Ignition Facility. Recently, high-foot implosions have demonstrated improved resistance to ablation-front Rayleigh-Taylor instability induced mixing of ablator material into the DT hot spot [Hurricane et al., Nature (London) 506, 343 (2014)]. Uranium hohlraums provide a higher albedo and thus an increased drive equivalent to an additional 25 TW laser power at the peak of the drive compared to standard gold hohlraums leading to higher implosion velocity. Additionally, we observe an improved hot-spot shape closer to round which indicates enhanced drive from the waist. In contrast to findings in the National Ignition Campaign, now all of our highest performing experiments have been done in uranium hohlraums and achieved total yields approaching 10^{16} neutrons where more than 50% of the yield was due to additional heating of alpha particles stopping in the DT fuel.

16.
Phys Rev Lett ; 114(17): 175001, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25978240

RESUMO

Recent experiments on the National Ignition Facility [M. J. Edwards et al., Phys. Plasmas 20, 070501 (2013)] demonstrate that utilizing a near-vacuum hohlraum (low pressure gas-filled) is a viable option for high convergence cryogenic deuterium-tritium (DT) layered capsule implosions. This is made possible by using a dense ablator (high-density carbon), which shortens the drive duration needed to achieve high convergence: a measured 40% higher hohlraum efficiency than typical gas-filled hohlraums, which requires less laser energy going into the hohlraum, and an observed better symmetry control than anticipated by standard hydrodynamics simulations. The first series of near-vacuum hohlraum experiments culminated in a 6.8 ns, 1.2 MJ laser pulse driving a 2-shock, high adiabat (α∼3.5) cryogenic DT layered high density carbon capsule. This resulted in one of the best performances so far on the NIF relative to laser energy, with a measured primary neutron yield of 1.8×10(15) neutrons, with 20% calculated alpha heating at convergence ∼27×.

17.
Rev Sci Instrum ; 86(4): 043503, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25933858

RESUMO

Neutron and x-ray imaging provide critical information about the geometry and hydrodynamics of inertial confinement fusion implosions. However, existing diagnostics at Omega and the National Ignition Facility (NIF) cannot produce images in both neutrons and x-rays along the same line of sight. This leads to difficulty comparing these images, which capture different parts of the plasma geometry, for the asymmetric implosions seen in present experiments. Further, even when opposing port neutron and x-ray images are available, they use different detectors and cannot provide positive information about the relative positions of the neutron and x-ray sources. A technique has been demonstrated on implosions at Omega that can capture x-ray images along the same line of sight as the neutron images. The technique is described, and data from a set of experiments are presented, along with a discussion of techniques for coregistration of the various images. It is concluded that the technique is viable and could provide valuable information if implemented on NIF in the near future.

18.
Phys Rev Lett ; 114(14): 145004, 2015 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-25910132

RESUMO

Experiments have recently been conducted at the National Ignition Facility utilizing inertial confinement fusion capsule ablators that are 175 and 165 µm in thickness, 10% and 15% thinner, respectively, than the nominal thickness capsule used throughout the high foot and most of the National Ignition Campaign. These three-shock, high-adiabat, high-foot implosions have demonstrated good performance, with higher velocity and better symmetry control at lower laser powers and energies than their nominal thickness ablator counterparts. Little to no hydrodynamic mix into the DT hot spot has been observed despite the higher velocities and reduced depth for possible instability feedthrough. Early results have shown good repeatability, with up to 1/2 the neutron yield coming from α-particle self-heating.

19.
Rev Sci Instrum ; 85(11): 11E614, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430360

RESUMO

Neutron and x-ray images are collected at the National Ignition Facility (NIF) to measure the size and shape of inertial confinement fusion implosions. The x-ray images provide a measure of the size and shape of the hot region of the deuterium-tritium fuel while the neutron images provide a measure of the size and shape of the burning plasma. Although these two types of images are collected simultaneously, they are not collected along the same line of sight (LOS). One 14 MeV neutron image is collected on the NIF equator, and two x-ray images are collected along the polar axis and nearly perpendicular to the neutron imaging line of sight on the equator. Both measurements use pinhole apertures to form the images, but existing x-ray imaging provides time-resolved measurements while the neutron images are time-integrated. Detailed comparisons of the x-ray and neutron images can provide information on the fuel assembly, but these studies have been limited because the implosions are not azimuthally symmetric and the images are collected along different LOS. We have developed a conceptual design of a time-integrated x-ray imaging system that could be added to the existing neutron imaging LOS. This new system would allow these detailed studies, providing important information on the fuel assembly of future implosions. Here we present this conceptual design and the expected performance characteristics.

20.
Rev Sci Instrum ; 85(2): 023508, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593362

RESUMO

The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the ignition stage of inertial confinement fusion (ICF) implosions at NIF. Since the neutron source is small (∼100 µm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-µm resolution are 20-cm long, single-sided tapers in gold. These apertures, which have triangular cross sections, produce distortions in the image, and the extended nature of the pinhole results in a non-stationary or spatially varying point spread function across the pinhole field of view. In this work, we have used iterative Maximum Likelihood techniques to remove the non-stationary distortions introduced by the aperture to reconstruct the underlying neutron source distributions. We present the detailed algorithms used for these reconstructions, the stopping criteria used and reconstructed sources from data collected at NIF with a discussion of the neutron imaging performance in light of other diagnostics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...